Job Locations
US-TX-Fort Worth
ID |
2025-2790
|
Category |
Data Center Operations
|
Department |
100 - Operations: COGS
|
Type |
Regular Full-Time
|
Overview
Senior MEP Technician is responsible for the day-to-day maintenance and service on the electrical - mechanical systems supporting the Data Center. The ideal candidate will have an extensive background in mechanical, electrical, and plumbing systems, with the ability to troubleshoot, maintain, and repair a wide range of building systems to ensure safe and efficient operations. Educate and train other TierPoint personnel on tasks related to the mechanical-electrical systems and components. Responsible for facility electrical / mechanical systems, documentation and ongoing service and support.
Responsibilities
Provides high quality, accurate, consistent, and efficient work for internal and external customer service surrounding the Company values
- Adopt and use defined systems, tools, procedures, processes, and standards
- Proactively manage ticket queue for timely request and response completion
- Manage and complete assigned projects and report progress
- Update documentation in a timely and accurate manner
- Perform all daily operational tasks
- Installation and termination of network and communication wiring
- Support and validate power infrastructure and deployment
- Provide remote hands and eyes support for internal or external client issues
- Ensure all aspects of the physical infrastructure are kept clean and orderly
- Perform routine physical inspections for alarm identification and operational issues
- Understand and follow escalation procedures
- Adhere to security procedures and controls
- Follow all safety guidelines and best practices
- In emergency situations, dispatch technicians and or vendors, as needed, in the absence of Management.
- Provide technical guidance to less experienced site personnel.
- Installation and termination of network, access control and communication wiring and components
- Record and maintain power metrics and other related details on a regular basis.
- Installation of new equipment and removal of systems as required
- Assist in the physical installation of computer equipment and components, cable tray, and cabling.
- Other responsibilities as required.
Electrical
- Significant experience in operating, troubleshooting, repairing and assisting in performance on preventative maintenance of TierPoint's electrical systems and components. These can include but are not limited to:
- Low and medium voltage switch gear, static transfer switches, power distribution units, remote power panels, branch circuits, large or medium voltage diesel generator systems, large UPS systems, building fire alarm / life safety, fire suppression systems and critical infrastructure monitoring systems.
- Install and repair connectivity demarcation units for electrical and telecommunications circuitry.
- Strong knowledge in all aspects of Data Center electrical operations.
HVAC/Plumbing
- Significant experience supporting HVAC and environmental operations
- Operate, troubleshoot, repair and perform preventative maintenance on TierPoint's mechanical systems and components. These can include but are not limited to: CRAC/CRAH units, condensing coils, rooftop units, chillers, cooling towers, and associated components for HVAC and plumbing systems.
- Strong knowledge in all aspects of Data Center mechanical operations.
Qualifications
Minimum Qualifications - Electrical
- Strong proficiency with the following:
- Multi-module or single module UPS systems
- Low and medium voltage switchgear
- Low and medium voltage diesel generators
- Raised floor or overhead bus power distribution
- PLC controls and components
- Exercise flexibility in challenging situations
- Ability to read and analyze blueprints and construction drawings including one line diagrams
- Excellent interpersonal and leadership skills to provide direction to Operations Technicians in absence of Management
- Working knowledge of automated building control systems
- Possesses and applies a broad knowledge of standards, practices and procedures of installing, testing and operating electrical and mechanical equipment. Usually works with limited supervision.
Minimum Qualifications - Mechanical/Plumbing
- Strong proficiency with the following:
- Datacenter HVAC and related components; ie CRAC/CRAH, chillers, cooling towers and rooftop units
- Plumbing/Piping and related components
- PLC controls and components
- Proven proficiency in the operation of 100% uptime data centers, critical facilities environment or industrial power systems
- Exercise flexibility in challenging situations
- Excellent oral and written communication and customer service skills
- Extensive experience with detailed record keeping and data entry accuracy
- Ability to read and analyze blueprints and construction drawings including one-line diagrams
- Working knowledge of automated building control systems
- Possesses and applies a broad knowledge of standards, practices and procedures of installing, testing and operating electrical and mechanical equipment. Usually works with limited supervision.
Preferred Qualifications
- 6 + years of technical training or related experience working in a mission critical building engineering operation.
- 3 + years as a Journeyman Electrician or HVAC Technician with satisfactory or better performance plus three years of industry experience.
- Associate degree in Electrical / Mechanical Engineering, Engineering / Mechanical Technology, Construction Management, a related field or equivalent experience.
- Current Journeyman or Master Electrician's license or Universal CFC Refrigeration License in good standing with the local authorities or equivalent experience.
- Technical training may be trade school or manufacturers training on UPS systems, medium voltage switchgear, low voltage power distribution units, building automation systems, 1.0 megawatt and larger engine-generator sets and/or large diesel engines, and other training directly related to the operation and maintenance of electrical / mechanical plant in a high reliability environment.
- Familiarity with ASHRAE, NEC and NFPA.
- Excellent verbal, written, and interpersonal skills
- Ability to work on multiple projects simultaneously
- Proficiency in using MS Office Suite and Windows-based computer applications
- Ability to use a ladder to work in elevated areas
Working Conditions
- Facility / construction environment
- Responding to 24x7 electrical and mechanical operational issues, which requires off-hour coverage
- Data center environment - sensitive computer equipment and complex power/cooling systems
- Ability to work in controlled environments and handle physical tasks such as lifting hardware or navigating confined spaces.
Pay Transparency TierPoint is committed to practices that promote pay equity and transparency. We provide a compensation range for roles that may be hired in locations with pay transparency law requirements. It's important to note the pay range may be narrower than displayed, as various factors are used to determine the offered compensation package including skill set, level of experience, geographic locations, and other relevant factors- i.e. budgetary requirements. Pay Range $35.65 - $57.83
|